The Intellical PHC101 series pH probes are digital, combination electrodes that measure the pH of wastewater, drinking water and general water samples. The probes have a non-refillable, gel-filled electrolyte and a built-in temperature sensor. The open reference junction gives an optimum electrical connection between the sample and the electrolyte and does not become clogged. The standard probes are for laboratory use. The rugged probes are for field use.
Features:

IntelliCAL PHC101 provides fast, stable response in wastewater applications - Unique solid gel probe and open reference junction specifically designed for pH measurement in wastewater.

IntelliCAL digital probes provide ultimate traceability in measurement history - Stored time and date stamp for each measurement, operator and sample ID, calibration history, parameter, and probe serial number

IntelliCAL digital probes alert the user when re-calibration is needed - No guesswork needed to provide the most reliable and accurate results with each measurement.

IntelliCAL digital probes can be moved between meters without the need to re-calibrate or re-enter measurement settings – Ideal for a multi-user environment with multiple HQD series Laboratory and Portable meters.

Applications:

Environmental remediation

Surface water

Ground water

Municipal water

Agriculture

Education

Storm water

Oil and Gas

Quantity must be 1 or more
Translation missing: en.products.product.equipment_available
Request a Quote

Specifications

Specifications

Accuracy:±0.02 pH
Application:Clean & Dirty Samples
Cable Length:1 m (3.28 ft)
Electrode Type:Non-Refillable Gel Reference Element
Junction:Open Junction
Kit?:No
Length:175 mm (6.89 in.)
Method Type:Field: Non-Refillable Gel Reference ELement
Parameter:pH
Probe Type:Standard
Product Kit:Model: PHC101
Accessories Included:None
Range:2 - 14 pH
Reference Type:Ag/AgCl
Resolution:0.001/0.01/0.1
Sample Depth:20 mm (0.79 in.)
Sensor Material:Epoxy
Sensor Type:pH Glass
Sodium (Alkalinity) error:-0.6 pH at pH 12.6 in 1 M NaOH
Special Features:Double junction reference
Temperature Accuracy:±0.3 °C (±0.54 °F)
Temperature Range:0 - 50 °C (32 - 122 °F)
Temperature Resolution:0.1 °C (0.18 °F)
Test Requirements:Parameter Needed: pH
Minimum Sample Depth (mm):20
Thermistor:ATC
Warranty:6 months
Weight:0.1 kg
What's Included?:IntelliCAL PHC101 Laboratory pH electrode with storage soaker bottle, 1 m cable, Test certificate, and Basic User Manual.